Thermo King TriPac Alarm Codes: Complete List (Evolution, TriPac, DPF)
Repair overview
The complete list of Thermo King TriPac APU alarm codes from Thermo King’s diagnostic manuals: the 19 numeric TriPac Evolution codes read in TK Monitor, the four [Eng], [AcS], [ALt] and [bAt] codes of the earlier TriPac, and the 27 flash codes of the optional DPF. For each one: the alarm name, whether it shuts the unit down, when it sets and what to check first. Most point to a sensor, a switch, the batteries or the refrigeration system. A few — like 35 Check Run Relay and 155 Lost CAN Communication — can mean the controller itself has failed, and those are the boards we repair.
Common Failure Symptoms We Fix
35 Check Run Relay (TriPac Evolution)
155 Lost CAN Communication (HMI to Interface Board)
[Eng] Alarm on the Earlier TriPac
Our Repair Process Includes:
- 50 TriPac Evolution, TriPac and DPF Alarm Codes
- Shutdown, Check, Log and Warning Types
- When Each Alarm Sets and What to Check First
Complete Thermo King TriPac alarm list (50 codes)
Identify your unit first: the TriPac Evolution uses numeric codes read in TK Monitor; the earlier TriPac shows [Eng], [AcS], [ALt] or [bAt] on the HMI; the optional DPF gives its own flash codes. Alarm names are shown as TK Monitor displays them.
TriPac Evolution (TK Monitor codes)
The HMI only lights the alarm icon (red = shutdown, yellow = check) and the group: ENG, ALT or ACS. The number is read in TK Monitor. Turning the system off and on at the HMI clears active alarms; if the cause is still there, the alarm returns.
| Code | Alarm | Type | When it sets and what to check |
|---|---|---|---|
| 02 | Check Evaporator Coil Sensor | Check | Reading outside -38 to 170 °F (-39 to 77 °C) for 10 s. Ohm-test the sensor in the evaporator box and its wires to J14 pins A9/B9. |
| 05 | Check Ambient Temperature Sensor (optional) | Check | Reading outside -38 to 170 °F for 10 s. Test the sensor on the condenser housing and its wires to J2 pins 4/5. |
| 06 | Check Engine Water Temperature Sensor (WT1) | Check | Reading outside -58 to 300 °F (-50 to 149 °C) for 10 s; the engine keeps running. Test WT1 and its wiring. |
| 10 | High Discharge Pressure | Check or Shutdown (ACS) | The high pressure cutout (HPCO, on the receiver/drier) opened at 360 psig; the compressor retries after 180 s. A third opening within 60 min shuts the unit down. Check pressures, condenser airflow and the HPCO (under 1 Ω closed). |
| 17 | Engine Failed to Crank | Log or Shutdown (ENG) | The engine did not reach 40 RPM within 3 s. Logged on the first try, shutdown after the second. Check battery voltage, the starter and its circuit. |
| 18 | High Engine Coolant Temperature | Shutdown (ENG) | WT1 above 220 °F (104 °C) for 10 s. Check coolant level, belt, radiator airflow, then the WT1 sensor (see code 06). |
| 19 | Low Engine Oil Pressure | Shutdown (ENG) | Oil pressure switch closed for 30 s with the engine running. Check oil level, then the switch and its LOPS wire (see code 31). |
| 20 | Engine Failed to Start | Log or Shutdown (ENG) | The engine cranked but did not reach 800 RPM within 30 s. Logged twice, shutdown after the third attempt. Check fuel supply, preheat and air intake. |
| 25 | Alternator Check | Shutdown (ALT) | Engine running and the battery discharging below 13.2 V for 3 min, or above 16.0 V for 3 min. Check the APU belt, alternator and power cable connections. |
| 31 | Check Oil Pressure Switch | Check | Before cranking, the oil pressure switch reads open (it should be closed with no oil pressure). Check the switch and the LOPS wire. |
| 35 | Check Run Relay | Shutdown (ENG) | No voltage on 8D 5 s after the run relay (on the interface board) is energized. Check the APU engine switch, 8X, the J4 option plug or DPF jumper, and any DPF alarm. If all are good, the relay on the board did not close. |
| 49 | Check Cab Temperature Sensor | Check | Reading outside -50 to 150 °F (-45 to 65 °C) for 30 s; A/C is disabled, heat still works. Test the cab sensor and its wiring. |
| 50 | Reset Clock | Log | The controller’s real-time clock lost its backup power. Set the time with TK Monitor; operation is not affected. |
| 54 | Test Mode Timeout | Shutdown | The unit stayed 15 min in the same Service Test Mode function. Leave test mode and restart. |
| 61 | Low or High Battery Voltage | Log or Shutdown (ALT) | Logged below 9.5 V during crank or preheat. Shutdown below 11.2 V or above 16 V for 3 min with the engine running. Check batteries, cables and charging. |
| 63 | Engine Stopped | Shutdown (ENG) | After a good start the engine fell below 100 RPM without being told to stop, often with no other alarm. Look for fuel starvation first. |
| 93 | Check Low Pressure Cutout | Log or Check | The low pressure cutout opened (5 psig) and the compressor retries every 60 s. Three times within 60 min becomes a Check alarm. Check the refrigerant charge and the switch. |
| 155 | Lost CAN Communication | Check | No CAN data from the HMI to the interface board for 2 s; the unit keeps the last settings. Check the HMI harness and the J34 connector, then try a known-good HMI, then the interface board. |
| 254 | Check Inlet Water Temperature Sensor (WT2) | Check | Reading outside -58 to 300 °F for 10 s; the pre-cooler fan and Arctic option are disabled. Test WT2 and its wiring. |
TriPac (Original, 1.0, 1.5 and 1.6 interface boards)
The pre-Evolution TriPac has four alarm codes, all shutdown alarms, shown in brackets on the HMI display. Turning the unit off at the HMI clears them; correct the cause and restart.
| Code | Alarm | Type | When it sets and what to check |
|---|---|---|---|
| [Eng] | Engine Alarm | Shutdown | No power at the board’s 8 input while 8FET is on: APU engine switch off, or the reset circuit tripped (low oil pressure, high coolant temperature or a failed start). On DPF units, the regeneration switch in Off or a DPF shutdown code. On 1.6 boards, a missing plug in the DPF option connector also sets it. |
| [AcS] | Air Conditioning System Alarm | Shutdown | No power at 7CLA while 7CL is on: the high pressure cutout opened. On units built before September 2006 (binary switch), the low pressure side can also set it. Check pressures, condenser airflow and the switch. |
| [ALt] | Alternator Alarm | Shutdown | D+ near 0 V 3 min after start: alternator regulator fault or D+ shorted to ground. Unplug the 2-wire plug at the alternator and run 3 min: if the alarm returns, check the D+ wiring; if not, test the alternator (13.8–14.2 V). |
| [bAt] | Battery Alarm | Shutdown | Battery voltage at the board’s 2 terminal fell to about 6–8 V and reset the board while the HMI stayed on. Needs HMI software r24+ and a 1.5 or later board. Battery must stay above 9 V while starting; check batteries, cables and the #2 circuit. |
TriPac DPF (SECM flash codes)
The DPF control module (SECM) flashes the red DPF FAULT light on the Exhaust Monitor: one flash, a pause, then three flashes = code 13. Count the cycle several times, as more than one code can be active. A DPF shutdown code also shows [Eng] on the TriPac HMI. To clear: record the codes, turn the truck ignition off, then hold the DPF Regeneration switch up for 2 s.
| Code | Alarm | Type | When it sets and what to check |
|---|---|---|---|
| 11 | Air Solenoid Relay Input | Shutdown | Circuit #67 open, shorted to ground or shorted to battery. Run the blower and air solenoid in System Test Mode and check wire #67. |
| 12 | Air Solenoid Relay Closed | Shutdown | Voltage on 2C while the relay should be off: relay stuck closed or 2C fed from elsewhere. |
| 13 | Air Solenoid Relay Open | Warning | No voltage on 2C while the relay should be on: relay not energized, open coil or stuck open. |
| 21 | Heater Contactor Input | Warning | Circuit #69 open, shorted to ground or shorted to battery. Run the heater contactor in System Test Mode and check wire #69. |
| 22 | Heater Contactor Closed | Shutdown | Voltage on HTRV while the contactor should be off: contactor stuck closed. |
| 23 | Heater Contactor Open | Warning | No voltage on HTRV while the contactor should be on: coil open or contactor stuck open. |
| 31 | Excessive High Ambient Air Temperature Input | Warning | Sensor signal near 5 V at SECM pin 8: sensor or ET circuit open. |
| 32 | Excessive Low Ambient Air Temperature Input | Warning | Sensor signal near 0 V: sensor or ET circuit shorted to ground. |
| 33 | High Ambient Air Temperature Range | Warning | Reads above 135 °C (275 °F). Check the real temperature behind the cab first (it can trap hot air), then the sensor and ET circuit. |
| 34 | Low Ambient Air Temperature Range | Warning | Reads below -50 °C (-58 °F): sensor or ET circuit shorted to ground. |
| 41 | Excessive High Back Pressure Input | Warning | Pressure transducer above about 4.7 V (≈175 in. of water). Run the transducer test and look for a real exhaust restriction. |
| 42 | Excessive Low Back Pressure Input | Warning | Transducer below about 0.2 V. Check EPI, EPN and P for opens, shorts to ground or poor connections. |
| 43 | High Back Pressure | Shutdown | Transducer above 2.5 V (≈80 in. of water, 20 kPa): the filter is full. A regeneration cycle is needed before the APU can run. |
| 44 | Out of Range Low Back Pressure | Warning | EPI below 0.12 V, a value no real pressure can produce. Check EPI for a short to ground or an open. |
| 45 | High Zero Back Pressure | Warning | 3 min after the engine stops, EPI has not dropped to 0.5–0.9 V. Run the transducer test and check the hose fitting at the exhaust vibrasorber. |
| 46 | Low Zero Back Pressure | Warning | With the engine off it reads below -2.5 kPa (0.22 V). Check the EPI wiring and the transducer. |
| 47 | Low Back Pressure | Warning | After 110 engine hours since the last regeneration, back pressure is still under 5 kPa (EPI under 1.0 V). Check the transducer, its hose and the exhaust path. |
| 51 | Consecutive Rapid Filter Loading | Warning | A regeneration was needed within 20 engine hours of the last one, 5 times in a row. Check for an ineffective regeneration cycle. |
| 52 | Maximum Time Reached Since Last Regeneration | Shutdown | No complete regeneration within 130 APU engine hours. Run a regeneration and check the back-pressure monitoring. |
| 53 | Maximum Low Voltage Aborted Regeneration | Warning | Two regenerations in a row stopped by voltage under 11.0 V. Check the truck alternator, batteries and connections. |
| 54 | Maximum Regenerations Reached with Pressure Fault | Shutdown | Second time-based regeneration in a row with a back-pressure code (41–47) active. Repair that code first, then regenerate. |
| 61 | ESIR & SIR Relay Control Input | Warning | Circuit #63 open, shorted to ground or shorted to battery. Run the ESIR and standby relays in System Test Mode and check wire #63. |
| 62 | FR Relay Control Input | Warning | Circuit #64 open, shorted to ground or shorted to battery. Check wire #64 with the driver’s switch on. |
| 71 | High 5V Supply Voltage | Warning | The SECM 5 V supply reads above 5.2 V. Unplug the back pressure transducer and measure P to EPN: it should be 5.0 V. |
| 72 | Low 5V Supply Voltage | Warning | The 5 V supply reads below 4.8 V. With the transducer unplugged: 5.0 V means a bad transducer; still low means the SECM. |
| 73 | High System Voltage | Warning | SECM power (2B-01) above 16.0 V. Confirm with a meter, then check the truck charging system. |
| 74 | Low System Voltage | Warning | SECM power below 8.0 V. Check battery charge and the voltage drop from the battery to the DPF heater contactor. |
Symptom Troubleshooting Guide
How to use the list above: identify which TriPac you have, find the code and check the item it names. Most TriPac alarms come from a sensor, a pressure switch, the batteries or the engine. When an alarm keeps returning after the sensor, switch and wiring test good — or when it names the run relay or CAN communication — the controller itself may be at fault.
| Symptom | Likely Causes | How We Repair It |
|---|---|---|
| Alarm 35 Check Run Relay on a TriPac Evolution | APU engine switch off, the J4 option plug or DPF jumper, an active DPF alarm, or the run relay on the interface board | Check the switch, 8X, the J4 plug and the DPF first. If 8X has voltage and 8D stays dead with the run relay energized, the relay on the board did not close — the interface board needs repair |
| Alarm 155 Lost CAN Communication | HMI harness, the J34 connector, the HMI or the interface board | Check the harness at both ends, then try a known-good HMI. If the alarm stays with a good HMI and harness, the interface board is next |
| [Eng] alarm on an earlier TriPac with no oil or temperature problem | Engine switch off, the reset circuit tripped by a failed start, the DPF switch or plug, or an open 8FET fuse | On Rev 1.6 boards the reset button does not pop out — press it anyway. Check the engine switch, the DPF switch and plug and fuse F8. If the 8 input still has no power, see our TriPac controller guide |
| A sensor alarm returns after the sensor was replaced | Wiring, or the board input for that sensor | Check the harness end to end. If it is good, the board input is the next suspect — repairable at component level |
Frequently Asked Questions
How do I read TriPac Evolution alarm codes?
The HMI only shows a red (shutdown) or yellow (check) alarm icon and the group: ENG, ALT or ACS. The numeric code is read in TK Monitor, which also clears alarms; they stay stored in the data logger.
How do I clear a TriPac alarm?
Turn the unit off and back on at the HMI. If the cause is still there, the alarm returns. DPF codes are cleared separately: record them, turn the truck ignition off and hold the DPF Regeneration switch up for 2 seconds.
What does [Eng] mean on a TriPac?
The interface board found no power at its 8 input while it was trying to run the engine: the engine switch is off, the reset circuit tripped (low oil pressure, high coolant temperature or a failed start), or on DPF units the regeneration switch is off or the DPF set a shutdown code.
Which alarms point to the controller?
Mainly 35 Check Run Relay and 155 Lost CAN Communication on the Evolution, and sensor or circuit alarms that keep returning after the wiring and the part test good. We repair TriPac Evolution and earlier TriPac interface boards at component level.
1-Year Warranty
Every repair ships back bench-tested, with a 1-year warranty on the components we repaired or replaced, plus 15 days of coverage for any other functional problem after delivery.
Start Your Repair NowWhy Choose DCF?
- $150 Diagnostic — Fully Waived When We Complete the Repair
- 7–15 Business-Day Standard Turnaround
- Component-Level Repair
- Miami-Based Facility
- Standard ground return shipping paid by DCF