The complete list of active alarm codes for the Carrier APX control system used on X4 7300 / 7500 and X2 trailer units, grouped as in Carrier’s APX Alarm Guide (62-12130): the code, the alarm name as the MessageCenter shows it, whether it shuts the unit down, and Carrier’s recommended action. Most alarms point to a sensor, a circuit or the refrigeration system. The microprocessor, communication (NO COMM) and board alarms are the ones that can mean the controller itself has failed — and those are the modules we repair.


Common Failure Symptoms We Fix

Microprocessor Alarms (00232–00255)

NO COMM Alarms Between Modules (21100–25100)

Board Alarms (INPBD1, OTBD1, STP)

Our Repair Process Includes:

  • 441 Active APX Alarm Codes
  • Shutdown vs. Alarm-Only Response
  • Carrier’s Recommended Action for Each Code

Complete Carrier APX alarm list (441 codes)

Alarm names are shown exactly as the unit’s MessageCenter displays them. “Restart” and “Reset” mean placing the START/RUN-OFF switch in OFF, then back in START/RUN.

Driver Alarms

CodeAlarmResponseWhat to do
00001Low Fuel Level WarningAlarm onlyAdd fuel; the alarm clears

Shutdown Alarms

CodeAlarmResponseWhat to do
00011Check / Low Engine Oil PressureShutdownRestart (switch OFF, then ON); report if it returns
00012High Coolant TempShutdownRestart (switch OFF, then ON); report if it returns
00013High PressureShutdownRestart (switch OFF, then ON); report if it returns
00014High A/C AmpShutdownRestart (switch OFF, then ON); report if it returns
00015High Battery VoltageShutdownReport and repair immediately
00016Low Battery VoltageShutdownReport and repair immediately
00017High Discharge TempShutdownRestart (switch OFF, then ON); report if it returns
00018Low Pressure Shut Down (Suction)ShutdownRestart (switch OFF, then ON); report if it returns
00019Low Fuel Level ShutdownShutdownAdd fuel; restart (switch OFF, then ON)
00020Maximum Compressor AlarmsShutdownReport and repair immediately
00021Tech ResetShutdownReport and repair immediately
00022Low Suction SuperheatShutdownRestart (switch OFF, then ON); report if it returns
00023Over CurrentShutdownRestart (switch OFF, then ON); report if it returns
00024Compression RatioShutdownRestart (switch OFF, then ON); report if it returns
00027High Suction PressureShutdownRestart (switch OFF, then ON); report if it returns
00028Low DeltaShutdownRestart (switch OFF, then ON); report if it returns
00029Check Heat CycleAlarm onlyReset (switch OFF, then ON); report if it returns

Startup / Engine Alarms

CodeAlarmResponseWhat to do
00030Failed to Run Minimum TimeShutdownReport and repair immediately
00031Auto Start FailShutdownReport and repair immediately
00034Engine Failed to StopAlarm onlyMove the fuel arm to the stop position (if equipped) or report and repair immediately
00035Engine Failed to CrankShutdownReport and repair immediately
00036Low Coolant TempAlarm onlyCheck and repair at end of trip
00037No Low SpeedAlarm onlyCheck and repair at end of trip
00038No High SpeedAlarm onlyCheck and repair at end of trip
00039Check Engine RPMShutdownRestart (switch OFF, then ON); report if it returns
00040Check Engine PreheatAlarm onlyRestart (switch OFF, then ON); report if it returns
00041Engine StalledShutdownRestart (switch OFF, then ON); report if it returns

Warning / Status Alarms

CodeAlarmResponseWhat to do
00051Alternator CheckShutdownReport and repair immediately
00053Temp out of RangeConfigurableReset (switch OFF, then ON); report if it returns
00054Defrost Terminated by TimeAlarm onlyCheck and repair at end of trip
00055Defrost OverrideAlarm onlyCheck and repair at end of trip
00056Check Evaporator Air FlowShutdownRestart (switch OFF, then ON); report if it returns
00057Door Open (Remote Switch 1)Configurable—
00058Door Open (Remote Switch 2)ConfigurableClose all compartment doors; the unit should restart. If it stays shut down, repair immediately
00059Data Recorder Memory FailAlarm onlyCheck and repair at end of trip
00060Real Time Clock FailureAlarm onlyCheck and repair at end of trip
00061Door OpenConfigurableClose all compartment doors; the unit should restart. If it stays shut down, repair immediately
00062Temp Out of Range Comp 2ConfigurableReset (switch OFF, then ON); report if it returns
00063Temp Out of Range Comp 3ConfigurableReset (switch OFF, then ON); report if it returns
00064Door Open OverrideAlarm onlyReset (switch OFF, then ON); report if it returns
00066Check Evap Sensor GroupAlarm onlyReset (switch OFF, then ON); report if it returns
00068Remote Evap 1 not ConfiguredAlarm only—

Electrical Alarms

CodeAlarmResponseWhat to do
00073No A/C Power (Standby)ConfigurableSwitch to diesel operation and repair
00074Phase ReversedShutdownRestart (switch OFF, then ON); report if it returns
00075Compressor Motor OverloadShutdownRestart (switch OFF, then ON); report if it returns
00076Condenser Motor OverloadShutdownRestart (switch OFF, then ON); report if it returns
00077Evaporator Motor Over LoadShutdownRestart (switch OFF, then ON); report if it returns
00078Check SV1 Solenoid ValveAlarm onlyReset (switch OFF, then ON); report if it returns
00079Check SV4 Solenoid ValveAlarm onlyReset (switch OFF, then ON); report if it returns
00080Check SV3 Solenoid ValveAlarm onlyReset (switch OFF, then ON); report if it returns
00081Check Fuel Heat RelayAlarm onlyCheck and repair at end of trip
00084Check Remote Alarm LightAlarm onlyCheck and repair at end of trip
00085Check UL-1Alarm onlyCheck and repair at end of trip
00086Check UL-2Alarm onlyCheck and repair at end of trip
00090Auto Fresh Air ExchangeAlarm onlyCheck and repair at end of trip
00091Check Heater Contactor 1Alarm onlyReset (switch OFF, then ON); report if it returns
00092Check Heater Contactor 2Alarm onlyReset (switch OFF, then ON); report if it returns
00093Check PrestartAlarm onlyReport and repair immediately
00094Check Compressor ContactorAlarm onlyReset (switch OFF, then ON); report if it returns
00095Check Condenser Motor Contactor 1Alarm onlyReset (switch OFF, then ON); report if it returns
00096Check Generator ContactorShutdownReset (switch OFF, then ON); report if it returns
00097Check Liquid Solenoid Valve (SV2)Alarm onlyReset (switch OFF, then ON); report if it returns
00098Check High Temp ThermostatAlarm onlyReset (switch OFF, then ON); report if it returns
00100Overload/Ground FaultShutdownReport and repair immediately
00101Evap Motor Overload C2ShutdownReport and repair immediately
00102Evap Motor Overload C3ShutdownReport and repair immediately
00103Check C2 Heater 1 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00104Check C2 Heater 2 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00105Check C3 Heater 1 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00106Check C3 Heater 2 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00109Check Evaporator Contactor CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00110Check C2 Evaporator CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00111Check C3 Evaporator CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00114Check LIV CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
00121Check Ambient Air SensorAlarm onlyCheck and repair at end of trip
00122Check Return Air SensorAlarm onlyIf shut down, repair immediately; otherwise report and repair at end of trip
00123Check Supply Air SensorAlarm only—
00124Check Defrost Termination SensorAlarm onlyCheck and repair at end of trip
00125Check Discharge Temp SensorAlarm onlyCheck and repair at end of trip
00126Low Fuel AlarmAlarm onlyCheck and repair at end of trip
00127Check Suction Temp SensorAlarm onlyCheck and repair at end of trip
00128Low Unbalanced AMPAlarm onlyCheck and repair at end of trip
00129Check Coolant Temp SensorAlarm onlyCheck and repair at end of trip
00130Check RPM SensorAlarm onlyIf shut down, repair immediately; otherwise report and repair at end of trip
00131Check Evaporator Outlet SensorAlarm onlyCheck and repair at end of trip
00132Check Defrost Termination SensorAlarm onlyCheck and repair at end of trip
00133Check Remote Sensor 1Alarm onlyCheck and repair at end of trip
00134Check Remote Sensor 2Alarm onlyCheck and repair at end of trip
00135Check Remote Sensor 3Alarm onlyCheck and repair at end of trip
00136Check C2 Supply Air SensorAlarm onlyCheck and repair at end of trip
00137Check C2 Return Air SensorAlarm onlyReset (switch OFF, then ON); report if it returns
00138Check C3 Return Air SensorAlarm onlyReset (switch OFF, then ON); report if it returns
00139Check C2 Defrost Termination SensorAlarm onlyCheck and repair at end of trip
00140Check C3 Defrost Termination SensorAlarm onlyCheck and repair at end of trip

Pretrip Alarms

CodeAlarmResponseWhat to do
00141Pretrip Aborted by UserAlarm onlyReport and repair immediately
00143Check Clutch CircuitAlarm onlyReport and repair immediately
00144Check UL1 CircuitAlarm onlyReport and repair immediately
00145Check Speed CircuitAlarm onlyReport and repair immediately
00146Check C2 Heater 1 CircuitAlarm onlyReport and repair immediately
00147Check C2 Heater 2 CircuitAlarm onlyReport and repair immediately
00148Check SV 1 CircuitAlarm onlyReport and repair immediately
00150Check SV 4 CircuitAlarm onlyReport and repair immediately
00151Check Engine Preheat CircuitAlarm onlyReport and repair immediately
00152Check FSA CircuitAlarm onlyReport and repair immediately
00153Check Return Air SensorAlarm onlyReport and repair immediately
00154Check Supply Air SensorAlarm onlyReport and repair immediately
00155Check Coolant Temp SensorAlarm onlyReport and repair immediately
00157Check Battery CircuitAlarm onlyReport and repair immediately
00158Check Ambient Air SensorAlarm onlyReport and repair immediately
00159Check Defrost Termination SensorAlarm onlyReport and repair immediately
00160Check Discharge Temp SensorAlarm onlyReport and repair immediately
00161Check Suction Temp SensorAlarm onlyReport and repair immediately
00162Check Auto Fresh AirAlarm onlyReport and repair immediately
00163Check C3 Heater 1 CircuitAlarm onlyReport and repair immediately
00164Check UL 2 CircuitAlarm onlyReport and repair immediately
00165Cannot Pump DownAlarm onlyReport and repair immediately
00166Check C2 Supply Air SensorAlarm onlyReport and repair immediately
00167Check C3 Heater 2 CircuitAlarm onlyReport and repair immediately
00168Cool LSV2Alarm onlyReport and repair immediately
00169Pre-Trip Economizer Circuit AlarmAlarm onlyReport and repair immediately
00170Check LIV CircuitAlarm onlyReport and repair immediately
00171System Not EqualizedAlarm onlyReport and repair immediately
00172Check BypassAlarm onlyReport and repair immediately
00173Check Economizer CircuitAlarm onlyReport and repair immediately
00174No Low SpeedAlarm onlyReport and repair immediately
00175No High SpeedAlarm onlyReport and repair immediately
00176Cool LSV3Alarm onlyReport and repair immediately
00177Check Evaporator SuperheatAlarm onlyReport and repair immediately
00178Check UL 1Alarm onlyReport and repair immediately
00179Check LIVAlarm onlyReport and repair immediately
00180Check SMVAlarm onlyReport and repair immediately
00181Check SV 4Alarm onlyReport and repair immediately
00182Check SV 1Alarm onlyReport and repair immediately
00183Check SV 3Alarm onlyReport and repair immediately
00184Check C2 Evaporator FanAlarm onlyReport and repair immediately
00185Check C3 Evaporator FanAlarm onlyReport and repair immediately
00186Check Evaporator Outlet TempAlarm onlyReport and repair immediately
00187Check Heater 1 CircuitAlarm onlyReport and repair immediately
00188Check Heater 2 CircuitAlarm onlyReport and repair immediately
00189Check Evaporator Fan MotorAlarm onlyReport and repair immediately
00190Check Condenser Fan Motor 1Alarm onlyReport and repair immediately
00191Check UL 2Alarm onlyReport and repair immediately
00192Check SV 2Alarm onlyReport and repair immediately
00194High Suction PressureAlarm onlyReport and repair immediately
00195Low Suction PressureAlarm onlyReport and repair immediately
00196High Discharge PressureAlarm onlyReport and repair immediately
00197Check ClutchAlarm onlyReport and repair immediately
00198Low Discharge PressureAlarm onlyReport and repair immediately
00199Check C2 RATAlarm onlyReport and repair immediately
00201Check UL 2 CylinderAlarm onlyReport and repair immediately
00202High Side LeakAlarm onlyReport and repair immediately
00203Check Discharge Check ValveAlarm onlyReport and repair immediately
00204Low Suction PressureShutdownReport and repair immediately
00205Check Defrost Termination SensorAlarm onlyReport and repair immediately
00206Check Condenser Fan Motor 1 CircuitAlarm onlyReport and repair immediately
00207Check Compressor Contactor CircuitAlarm onlyReport and repair immediately
00208Check Generator Contactor CircuitAlarm onlyReport and repair immediately
00209Check Standby Contactor CircuitAlarm onlyReport and repair immediately
00210Check C3 RATAlarm onlyReport and repair immediately
00211Check C2 Defrost Termination SensorAlarm onlyReport and repair immediately
00212Check C3 Defrost Termination SensorAlarm onlyReport and repair immediately
00217Check Electric Fuel Pump CircuitAlarm onlyReport and repair immediately
00218Check Electric Heater for Compartment 1Alarm onlyReport and repair immediately
00219Check Electric Heater for Compartment 2Alarm onlyReport and repair immediately
00220Check Electric Heater for Compartment 3Alarm onlyReport and repair immediately

Maintenance Alarms

CodeAlarmResponseWhat to do
00223Maintenance Hour Meter-Total DieselAlarm onlyCheck and repair at end of trip
00224Maintenance Hour Meter-Total StandbyAlarm onlyCheck and repair at end of trip
00225Maintenance Hour Meter-Total SwitchAlarm onlyCheck and repair at end of trip
00226Maintenance Hour Meter 1Alarm onlyCheck and repair at end of trip
00227Maintenance Hour Meter 2Alarm onlyCheck and repair at end of trip
00228Maintenance Hour Meter 3Alarm onlyCheck and repair at end of trip
00229Maintenance Hour Meter 4Alarm onlyCheck and repair at end of trip
00230Maintenance Hour Meter 5Alarm onlyCheck and repair at end of trip

Microprocessor Alarms

CodeAlarmResponseWhat to do
00232Non-Valid SetpointShutdownReset (switch OFF, then ON); report if it returns
00233Non-Valid Model NumberShutdownReset (switch OFF, then ON); report if it returns
00237Non-Valid Functional ParameterShutdownReset (switch OFF, then ON); report if it returns
00238Non-Valid Configuration ParameterShutdownReset (switch OFF, then ON); report if it returns
00242Discharge Pressure Transducer CalibrationShutdownReset (switch OFF, then ON); report if it returns
00243Suction Pressure Transducer CalibrationShutdownReset (switch OFF, then ON); report if it returns
00244Economizer Pressure Transducer CalibrationShutdownReset (switch OFF, then ON); report if it returns
00245Cannot Save SettingsAlarm onlyReset (switch OFF, then ON); report if it returns
00246Eprom Write FailureAlarm onlyReset (switch OFF, then ON); report if it returns
00248Configuration ErrorShutdownReset (switch OFF, then ON); report if it returns
00255System FailureShutdownReset (switch OFF, then ON); report if it returns

Alarms 2000–2999

CodeAlarmResponseWhat to do
02000Software IncompatibilityShutdownReport and repair immediately
02001Rear Panel ShutdownShutdownReport and repair immediately
02002Low Discharge SuperheatShutdownReport and repair immediately
02003Display FailureShutdownReport and repair immediately
02004Out of Range HighShutdownReport and repair immediately
02005Coil Over TempShutdownReport and repair immediately
02006Starter Output FailureShutdownReport and repair immediately

Startup / Engine Alarms 3000–3999

CodeAlarmResponseWhat to do
03000Motor Overload #1ShutdownReport and repair immediately
03001Throttle Position SensorAlarm onlyReset (switch OFF, then ON); report if it returns
03002Check Clutch SlipShutdownReport and repair immediately
03003No medium speedAlarm onlyReset (switch OFF, then ON); report if it returns

Warning / Status Alarms 4000–4999

CodeAlarmResponseWhat to do
04000Door Open (Remote Switch 3)ConfigurableReset (switch OFF, then ON); report if it returns
04001Door Open (Remote Switch 4)ConfigurableReset (switch OFF, then ON); report if it returns
04002High Economizer SuperheatAlarm onlyReset (switch OFF, then ON); report if it returns
04004No Setpoint ChangeAlarm onlyRe-enter the setpoint
04005No Setpoint Change Comp 2Alarm onlyRe-enter the setpoint
04006No Setpoint Change Comp 3Alarm onlyRe-enter the setpoint
04007Remote Evap 2 Not ConfiguredAlarm onlyReport and repair immediately
04008Remote Evap 3 Not ConfiguredAlarm onlyReport and repair immediately
04016Check EESAlarm onlyReset (switch OFF, then ON); report if it returns
04017Main Micro Reset BlockedAlarm onlyClears when the third-party download is complete

Electrical Alarms 5000–5999

CodeAlarmResponseWhat to do
05002Check Fuel Pump RelayAlarm onlyReport and repair immediately
05003Check Diesel/Electric RelayAlarm onlyReport and repair immediately
05004Bad F8 FuseAlarm onlyReset (switch OFF, then ON); report if it returns
05005Bad F10 FuseAlarm onlyReset (switch OFF, then ON); report if it returns
05006Power Enable Fuse AlarmAlarm onlyReport and repair immediately
05007F-3 BlownAlarm onlyReport and repair immediately
05008Bad F10 FuseAlarm onlyReport and repair immediately
05009Check Standby Contactor 1ShutdownReport and repair immediately
05010Check Standby Contactor 2ShutdownReport and repair immediately
05011Check High SpeedAlarm onlyReport and repair immediately
05012Check ENCU PowerAlarm onlyReport and repair immediately
05013Check Clutch CircuitAlarm onlyReport and repair immediately
05014Check Starter CircuitAlarm onlyReport and repair immediately
05015Check Three Way Valve CircuitAlarm onlyReport and repair immediately
05016Check Remote Light BarAlarm onlyReset (switch OFF, then ON); report if it returns
05017Check Preheat CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
05018Check PER CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
05019Check CDCON 2 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
05020Check Heater Contactor 1 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
05021Check Heater Contactor 2 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
05022Check C2 High Temp ThermostatAlarm onlyReset (switch OFF, then ON); report if it returns
05023Check C3 High Temp ThermostatAlarm onlyReset (switch OFF, then ON); report if it returns
05024Standby MotorShutdownReport and repair immediately
05025Check Power Source ContactorShutdownReport and repair immediately
05026Check A/C PhaseShutdownReport and repair immediately
05027Generator OverheatShutdownReport and repair immediately
05028Bad PM Fuse 2ShutdownReport and repair immediately
05029Bad PM Fuse 3/5/7Alarm onlyReport and repair immediately
05030Bad PM Fuse 4ShutdownReport and repair immediately
05031Bad PM Fuse 10ShutdownReport and repair immediately
05032Bad PM Fuse 11ShutdownReport and repair immediately
05033Check PER CircuitShutdownReport and repair immediately
05034Check PER ContactsShutdownReport and repair immediately
05035EVXV FaultAlarm onlyReport and repair immediately
05036ECXV FaultAlarm onlyReport and repair immediately
05037SMV FaultAlarm onlyReport and repair immediately
05038Compartment 2 EVXV1 FaultAlarm onlyReport and repair immediately
05039Compartment 2 EVXV2 FaultAlarm onlyReport and repair immediately
05040Compartment 3 EVXV1 FaultAlarm onlyReport and repair immediately
05041Compartment2 EVXV2 FaultAlarm onlyReport and repair immediately
05042Auxiliary Battery Voltage HighAlarm onlyReset (switch OFF, then ON); report if it returns
05043Auxiliary Battery Voltage LowAlarm onlyReset (switch OFF, then ON); report if it returns
05044Stepper Board Voltage LowAlarm onlyReset (switch OFF, then ON); report if it returns
05045Inverter Contactor AlarmAlarm onlyReport and repair immediately
05046DC Battery Contactor AlarmAlarm onlyReport and repair immediately
05047Inverter output alarmAlarm onlyReport and repair immediately
05048Check liquid SV1Alarm onlyReport and repair immediately
05049Check liquid SV2Alarm onlyReport and repair immediately
05050Check liquid SV3Alarm onlyReport and repair immediately
05051Check hot gas SV1Alarm onlyReport and repair immediately
05052Check hot gas SV2Alarm onlyReport and repair immediately
05053Check hot gas valve SV3Alarm onlyReport and repair immediately
05054Check MHVAlarm onlyReport and repair immediately
05055Check Flash RelayAlarm onlyReport and repair immediately
06000Condenser Fan 2 OverloadShutdownReport and repair immediately
06002Compressor Protect ModeShutdownReset (switch OFF, then ON); report if it returns
06003Check Evaporator Fan 2 CircuitAlarm onlyReport and repair immediately
06004Check Defrost Drain Heater CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
06005Check Electric/Water Heat CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
06006Defrost Drain Heater C2Alarm onlyReset (switch OFF, then ON); report if it returns
06007Defrost Drain Heater C3Alarm onlyReset (switch OFF, then ON); report if it returns

Sensor Alarms 7000–7999

CodeAlarmResponseWhat to do
07000Check Economize Temp SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07001Check Economizer Pressure TransducerAlarm onlyReset (switch OFF, then ON); report if it returns
07002Check C3 Supply Air SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07003Check C2 Evaporator Outlet SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07004Check C3 Evaporator Outlet SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07005Check Engine OP Switch (TDO)Alarm onlyReset (switch OFF, then ON); report if it returns
07006Check Suction Pressure TransducerAlarm onlyReset (switch OFF, then ON); report if it returns
07007Compressor A/C CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
07008Check Redundant RATAlarm onlyReset (switch OFF, then ON); report if it returns
07009RAT Temp Sensor Out of RangeAlarm onlyReset (switch OFF, then ON); report if it returns
07010Check Redundant SATAlarm onlyReset (switch OFF, then ON); report if it returns
07011Check Evaporator Pressure SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07012Check Economizer Pressure SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07013Check Compressor Discharge Pressure SensorAlarm onlyReset (switch OFF, then ON); report if it returns
07014Check C2 Redundant RATAlarm onlyReset (switch OFF, then ON); report if it returns
07015C2 RAT Temp Sensor Out of RangeAlarm onlyReset (switch OFF, then ON); report if it returns
07016Compressor High PowerAlarm onlyReset (switch OFF, then ON); report if it returns

Pretrip Alarms 11000–17999

CodeAlarmResponseWhat to do
11000Check Condenser Fan Motor 2Alarm onlyReset (switch OFF, then ON); report if it returns
11001Check Standby Contactor CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
11002Check Hot Gas Valve (Supra)Alarm onlyReset (switch OFF, then ON); report if it returns
11003Check Evap Fan 1 & 2 (Supra)Alarm onlyReset (switch OFF, then ON); report if it returns
11004Check Evap Fan 3 (Supra)Alarm onlyReset (switch OFF, then ON); report if it returns
11005Check Defrost Drain Heater 2Alarm onlyReset (switch OFF, then ON); report if it returns
11006Check Defrost Drain Heater 3Alarm onlyReset (switch OFF, then ON); report if it returns
11007Check Hot Gas Valve 2Alarm onlyReset (switch OFF, then ON); report if it returns
11008Check Hot Gas Valve 3Alarm onlyReset (switch OFF, then ON); report if it returns
11009Check Main Heat ValveAlarm onlyReset (switch OFF, then ON); report if it returns
11010Check Liquid Valve 1Alarm onlyReset (switch OFF, then ON); report if it returns
11011Check Liquid Valve 2Alarm onlyReset (switch OFF, then ON); report if it returns
11012Check Liquid Valve 3Alarm onlyReset (switch OFF, then ON); report if it returns
11017Check VFDAlarm onlyReset (switch OFF, then ON); report if it returns
12000Check Supply Air Sensor C3Alarm onlyReset (switch OFF, then ON); report if it returns
12001Check EVOT Sensor C2Alarm onlyReset (switch OFF, then ON); report if it returns
12002Check EVOT Sensor C3Alarm onlyReset (switch OFF, then ON); report if it returns
12003Check Economizer SensorAlarm onlyReset (switch OFF, then ON); report if it returns
13000Check Condenser Fan 2 CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
13001Check Hot Gas Valve Circuit (Supra)Alarm onlyReset (switch OFF, then ON); report if it returns
14000Check Evap 1 Superheat C2Alarm onlyReset (switch OFF, then ON); report if it returns
14001Check Evap 2 Supreheat C2Alarm onlyReset (switch OFF, then ON); report if it returns
14003Check Evap 2 Supreheat C3Alarm onlyReset (switch OFF, then ON); report if it returns
14004Check Hot Gas Valve for Compartment 1Alarm onlyReset (switch OFF, then ON); report if it returns
14005Check Hot Gas Valve 2 for Compartment 2Alarm onlyReset (switch OFF, then ON); report if it returns
14005Check Hot Gas Valve for Compartment 3Alarm onlyReset (switch OFF, then ON); report if it returns
14006Check Hot Gas Valve 3 for Compartment 3Alarm onlyReset (switch OFF, then ON); report if it returns
14007Check Main Heat ValveAlarm onlyReset (switch OFF, then ON); report if it returns
14008Check Liquid Valve for Compartment 1Alarm onlyReset (switch OFF, then ON); report if it returns
14009Check Liquid Valve 2 for Compartment 2Alarm onlyReset (switch OFF, then ON); report if it returns
14010Check Liquid Valve 3 for Compartment 3Alarm onlyReset (switch OFF, then ON); report if it returns
15001No Medium Speed (Supra)Alarm onlyReset (switch OFF, then ON); report if it returns
15005Check Very High Speed RPMAlarm onlyReset (switch OFF, then ON); report if it returns
16000Check High Pressure SwitchAlarm onlyReset (switch OFF, then ON); report if it returns
16001No Alarm 13Alarm onlyReset (switch OFF, then ON); report if it returns
17000Check EES Air Control ValveAlarm onlyReset (switch OFF, then ON); report if it returns
17001Check EES Fueling SystemAlarm onlyReset (switch OFF, then ON); report if it returns

GTD Alarms

CodeAlarmResponseWhat to do
20100No communication from Micro to DisplayAlarm onlyReport and repair immediately
20101No communication from Micro to Remote DisplayAlarm onlyReport and repair immediately

MMB Alarms

CodeAlarmResponseWhat to do
21100No Comm from Micro to any ModuleShutdownReport and repair immediately

INPBD1 Alarms (Input Board)

CodeAlarmResponseWhat to do
22100No Comm from Micro to Input Board 1ShutdownReport and repair immediately
22101Input Voltage Low to Input Board 1Alarm onlyReset (switch OFF, then ON); report if it returns
22102Input Voltage High to Input Board 1Alarm onlyReset (switch OFF, then ON); report if it returns
22103Configuration Error Input Board 1ShutdownReport and repair immediately
22400MSM1 Input CAN FailShutdownReport and repair immediately
22401MSM1 Input Voltage LowAlarm onlyReset (switch OFF, then ON); report if it returns
22402MSM1 Input Voltage HighAlarm onlyReset (switch OFF, then ON); report if it returns
22403MSM1 Input Lost ConfigurationShutdownReport and repair immediately
22500No Comm from MSM2 to Input BoardShutdownReport and repair immediately
22501Sensor Input Voltage Low to MSM2Alarm onlyReset (switch OFF, then ON); report if it returns
22502Sensor Input Voltage High to MSM2Alarm onlyReset (switch OFF, then ON); report if it returns
22503Configuration Error MSM2ShutdownReport and repair immediately
22800No Comm from MCA to Input BoardShutdownReport and repair immediately
22801Sensor Input Voltage Low to MCAAlarm onlyReset (switch OFF, then ON); report if it returns
22802Sensor Input Voltage High to MCAAlarm onlyReset (switch OFF, then ON); report if it returns
22803Configuration Error MCAShutdownReport and repair immediately

OTBD1 Alarms (Output Board)

CodeAlarmResponseWhat to do
23100No Comm from Micro to Output Board 1ShutdownReport and repair immediately
23101Configuration Error Output Board 1ShutdownReport and repair immediately
23800PM CAN FailShutdownReport and repair immediately
23801Power Module Lost ConfigurationShutdownReport and repair immediately
23803Configuration Error TPCShutdownReport and repair immediately

CCB Alarms

CodeAlarmResponseWhat to do
24100No Comm for CCB1ShutdownReport and repair immediately
24101Sensor Input Voltage Low to CCB1Alarm onlyReset (switch OFF, then ON); report if it returns
24102Sensor Input Voltage High to CCB1Alarm onlyReset (switch OFF, then ON); report if it returns
24103CCB Lost ConfigurationShutdownReport and repair immediately
24200CCB CAN FailShutdownReport and repair immediately
24201Sensor Input Voltage Low to CCB2Alarm onlyReset (switch OFF, then ON); report if it returns
24202Sensor Input Voltage High to CCB2Alarm onlyReset (switch OFF, then ON); report if it returns
24203CCB Lost ConfigurationShutdownReport and repair immediately
24300No Comm for CCB3ShutdownReport and repair immediately
24301Sensor Input Voltage Low to CCB3Alarm onlyReset (switch OFF, then ON); report if it returns
24302Sensor Input Voltage High to CCB3Alarm onlyReset (switch OFF, then ON); report if it returns
24303CCB3 Lost ConfigurationShutdownReport and repair immediately
24400No Comm for CCB4ShutdownReport and repair immediately
24401Sensor Input Voltage Low to CCB4Alarm onlyReset (switch OFF, then ON); report if it returns
24402Sensor Input Voltage High to CCB4Alarm onlyReset (switch OFF, then ON); report if it returns
24403CCB4 Lost ConfigurationShutdownReport and repair immediately

STP Alarms (Stepper Valve Module)

CodeAlarmResponseWhat to do
25100No Comm from Stepper 1ShutdownReport and repair immediately
25101Stepper 1 Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25102Input Voltage Out of Range Stepper 1Alarm onlyReset (switch OFF, then ON); report if it returns
25200No Comm from Stepper 2ShutdownReport and repair immediately
25201Stepper 2 Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25202Input Voltage Out of Range Stepper 2Alarm onlyReset (switch OFF, then ON); report if it returns

ENCU1 Alarms (Engine Control Unit)

CodeAlarmResponseWhat to do
25300No Comm from Stepper 3ShutdownReport and repair immediately
25301Stepper 3 Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25302Input Voltage Out of Range Stepper 3Alarm onlyReset (switch OFF, then ON); report if it returns
25400No Comm from Stepper 4ShutdownReport and repair immediately
25401Stepper 4 Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25402Input Voltage Out of Range Stepper 4Alarm onlyReset (switch OFF, then ON); report if it returns
25500Tri-Stepper CAN FailShutdownReport and repair immediately
25501Tri-Stepper Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25502Tri-Stepper Input VoltageAlarm onlyReset (switch OFF, then ON); report if it returns
25503Tri-Stepper Lost ConfigShutdownReport and repair immediately
25600No Comm from Tri-Stepper 2ShutdownReport and repair immediately
25601Tri-Stepper 2 Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25602Input Voltage Out of Range Tri-Stepper 2Alarm onlyReset (switch OFF, then ON); report if it returns
25603Configuration Error Tri-Stepper 2ShutdownReport and repair immediately
25800No Comm from SIOBShutdownReport and repair immediately
25801SIOB Over CurrentAlarm onlyReset (switch OFF, then ON); report if it returns
25802Input Voltage Out of Range SIOBAlarm onlyReset (switch OFF, then ON); report if it returns
25803Configuration Error SIOBShutdownReport and repair immediately
26100No Comm from ENCUShutdownReport and repair immediately
26101Engine OverheatEngineering event—
26102Water Temp Sensor LowEngineering event—
26103Water Temp Sensor HighEngineering event—
26104Battery Voltage HighEngineering event—
26105Engine Overrun (Kubota)ShutdownReport and repair immediately
26106Sensor Supply Voltage to ENCU LowShutdownReport and repair immediately
26108Rack Position Sensor AbnormalEngineering event—
26109Check Actuator (Kubota)ShutdownReport and repair immediately
26110Check RPM Sensor (Kubota)ShutdownReport and repair immediately
26162Water in FuelAlarm onlyReport and repair immediately

EES Alarms

CodeAlarmResponseWhat to do
26200No Comm form EES ModuleAlarm onlyReset (switch OFF, then ON); report if it returns
26201EES Service RequiredAlarm onlyReset (switch OFF, then ON); report if it returns
26202EES High Back PressureAlarm onlyReset (switch OFF, then ON); report if it returns
26203EES Low Back PressureAlarm onlyReset (switch OFF, then ON); report if it returns
26204EES ECU Low VoltageAlarm onlyReset (switch OFF, then ON); report if it returns
26205EES Filter Inlet TempAlarm onlyReset (switch OFF, then ON); report if it returns
26206EES Check Fuel Pump CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
26207EES Check Air Control ValveAlarm onlyReset (switch OFF, then ON); report if it returns
26208EES Check Fuel Injection CircuitAlarm onlyReset (switch OFF, then ON); report if it returns
26209EES Filter Outlet TempAlarm onlyReset (switch OFF, then ON); report if it returns
26210EES Exhaust Inlet TempAlarm onlyReset (switch OFF, then ON); report if it returns
26211EES ECU Output FailureAlarm onlyReset (switch OFF, then ON); report if it returns
26212EES ECU Log FailureAlarm onlyReset (switch OFF, then ON); report if it returns
26213EES ECU Clock FailureAlarm onlyReset (switch OFF, then ON); report if it returns
26214EES ECU Temp LowAlarm onlyReset (switch OFF, then ON); report if it returns
26215EES ECU Temp HighAlarm onlyReset (switch OFF, then ON); report if it returns
26216EES No Temp RiseAlarm onlyReset (switch OFF, then ON); report if it returns
26217EES System FailureShutdownReport and repair immediately
26218EES System OvertempShutdownReport and repair immediately
26219EES Temp Sensor DriftAlarm onlyReset (switch OFF, then ON); report if it returns
26220EES Back Pressure ExceededAlarm onlyReset (switch OFF, then ON); report if it returns
26221EES Frequent RegenerationAlarm onlyReset (switch OFF, then ON); report if it returns
26222EES Back Pressure Offset ExceededAlarm onlyReset (switch OFF, then ON); report if it returns

Engine Alarms

CodeAlarmResponseWhat to do
26300ENCU Comm FailureShutdownReport and repair immediately
26301ENCU Alarm (PCODE/SPN)ShutdownReport and repair immediately
26302ENCU Alarm (PCODE/SPN)Alarm onlyReport and repair immediately
26500Incompatible ENCUShutdownReport and repair immediately

Communication Alarms

CodeAlarmResponseWhat to do
27100Loss of Communication to Comm ModuleShutdownReport and repair immediately
27200Loss of Communication to Optional Comm ModuleAlarm onlyReport and repair immediately
28001No Comm from Fuel SensorAlarm onlyReset (switch OFF, then ON); report if it returns
28002No Comm from Door SwitchAlarm onlyReset (switch OFF, then ON); report if it returns
28003Invalid 3rd Party Door SwitchAlarm onlyReset (switch OFF, then ON); report if it returns
28004Invalid 3rd Party REMS1Alarm onlyReset (switch OFF, then ON); report if it returns
28005Invalid 3rd Party REMS2Alarm onlyReset (switch OFF, then ON); report if it returns
28006Invalid 3rd Party REMS3Alarm onlyReset (switch OFF, then ON); report if it returns
28007Invalid 3rd Party REMS4Alarm onlyReset (switch OFF, then ON); report if it returns
28008No Comm From Fuel Flow MeterAlarm onlyReset (switch OFF, then ON); report if it returns
29000Alternator Electric IssueShutdownReport and repair immediately
29001Alternator High TempShutdownReport and repair immediately
29002Alternator Belt BrokenShutdownReport and repair immediately
29003Alternator Belt SlipAlarm onlyReset (switch OFF, then ON); report if it returns
29004LIN Comm ErrorAlarm onlyReset (switch OFF, then ON); report if it returns
29005LIN Comm TimeoutAlarm onlyReset (switch OFF, then ON); report if it returns
29006No Comm to AlternatorShutdownReport and repair immediately
29007Power FrequencyAlarm onlyReset (switch OFF, then ON); report if it returns

Symptom Troubleshooting Guide

How to use the list above: find the code shown on the MessageCenter, check whether it shuts the unit down, and follow the recommended action. When an alarm keeps returning after the sensor, wiring or component it names has been checked — or when it is a microprocessor, NO COMM or board alarm — the controller module itself may be at fault.

SymptomLikely CausesHow We Repair It
An alarm returns after restarting the unitThe condition is still present: the sensor, circuit or system the alarm namesRecord the alarm before clearing it, as Carrier recommends, then check the item it names. Report every reactivation
Microprocessor alarms (00232–00255) that will not clearInvalid or unwritable data in the main microprocessor memory, or software that needs an updateRe-enter the setting and update the software. If the alarm remains, the main microprocessor module needs repair
NO COMM alarms (21100–25100)The main microprocessor lost a module on the CAN bus: wiring, connector pins, or the module itselfLook at how many NO COMM alarms are active: several point to the wiring or the main microprocessor, a single one points to the module it names
Sensor or circuit alarms that return after the part was replacedWiring, or the controller’s input or output circuit for that sensor or componentCheck the wiring end to end. If it is good, the controller input or driver is the next suspect — repairable at component level

Frequently Asked Questions

What is the difference between a Shutdown and an Alarm-only code?

A shutdown alarm stops the unit; an alarm-only code lets it keep running while it warns you. Carrier marks some alarms as configurable, so they can be set as either one.

How do I clear an APX alarm?

Carrier recommends recording every alarm before clearing it. Alarms that say to reset or restart are cleared by placing the START/RUN-OFF switch in OFF and then back in START/RUN; if the condition is still there, the alarm returns.

Does this list apply to the X4 Series 8?

X4 7300 / 7500 Series 8 units (serial UAJ91657524 and later) also use the APX control system, but their microprocessor hardware is different: a Microprocessor Stepper Module (MSM) and a Power Module (PM) instead of separate main microprocessor and stepper valve modules. Some alarms change with the software revision, so check your unit’s manual.

Which alarms point to the controller?

Mainly the microprocessor alarms (00232–00255), the NO COMM and module alarms (21100–25100, INPBD1, OTBD1, STP) and circuit alarms that keep returning after the wiring and the component check good. We repair the APX main microprocessor and the stepper valve module at component level.

Alarm codes, names, responses and actions come from Carrier’s Alarm Guide for APX, Advance and Aspen controls (62-12130 Rev D, APX section); codes Carrier marks as future expansion or not currently active are left out. Software revisions change some alarms, so always cross-check your unit’s own manual. This is an independent reference by DCF Electronic, not a Carrier publication.

1-Year Warranty

Every repair ships back bench-tested, with a 1-year warranty on the components we repaired or replaced, plus 15 days of coverage for any other functional problem after delivery.

Start Your Repair Now

Why Choose DCF?

  • $150 Diagnostic — Fully Waived When We Complete the Repair
  • 7–15 Business-Day Standard Turnaround
  • Component-Level Repair
  • Miami-Based Facility
  • Standard ground return shipping paid by DCF

Guide: Repaired vs. Remanufactured vs. New →

How to ship your unit →

Repair terms and warranty →

Have Questions?

Not sure if this is your part? Send us a picture.

Contact Support